
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 6 - Jul 11
For Your Every Summer RSVP, with Code: SUMMER15
Description
HYDRON MEMBRANE BW-4040 COMMERCIAL MEMBRANE - 2400 GPDBW 4040 HYDRON COMMERCIAL MEMBRANES Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, HYDRON recommends removing residual free chlorine by pre treatment prior to membrane exposure. Any specific application must be limited within the extreme operating conditions. We strongly recommend you to refer to the latest edition of
BW-4040 HYDRON COMMERCIAL MEMBRANES
Under certain conditions, the presence of free chlorine and other oxidizing agents
will cause premature membrane failure. Since oxidation damage is not covered under
warranty, HYDRON recommends removing residual free chlorine by pre treatment prior to membrane exposure. Any specific application must be limited within the extreme operating conditions. We strongly recommend you to refer to the latest edition of technology manual and design guide prepared by HYDRON Membrane Technology or consult experts proficient in membrane technology. In case the customer fails to follow the operating conditions as specified in this manual, HYDRON Membrane Technology will assume no liability for all results. The permeate flow listed in the table is the average value. The permeate flow of single membrane element is within a tolerance not exceeding ±20% of nominal value.
Discard the RO- filtered water produced during the first one hour after system start-up.
During storage time and run time, it is strictly prohibited to dose any chemical medicament that may be harmful.
MEMBRANE TYPE Polyamide Compound
TESTING CONDITIONS
› Testing Pressure 225 psi (1.55 MPa) (15.5 bar)
› Temperature of Testing Solution 77 °F (25 °C)
› Concentration of Testing Solution (NaCl) 2000 ppm
› pH Value of Testing Solution 7.5
› Recovery Rate of Single Membrane Element 15%
EXTREME OPERATION CONDITIONS
› Max. Working Pressure 600 psi (4.14 MPa) (41.4 bar)
› Max. Feed water Flow 16 gpm (3.6 m3
/hr)
› Max. Feed water Temperature 113 °F (45 °C)
› Max. Feed water SDI 5
› Single Membrane Max. Pressure Drop 15 psi (0.1 MPa) (1.03 bar)
› Residual chlorine Concentration
of Feed water <0.1 ppm
› pH Range of Feed water
during Continuous Operation 3~10
› pH Range of Feed water during Chemical Cleaning 2~12
HYDRON Commercial Membrane Elements with their hard shell
fiberglass exterior provide outstanding performance for Commercial
systems. HYDRON Membranes are manufactured in a State-of-the-
Art, ISO-9001-2000 certified automatic rolling facility which provides
you with a precise and advanced membrane element.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy